Commercial roofs · Leesburg

Commercial roofing in Leesburg, FL

Hurricane Irma left 10.13 inches of rain on a Leesburg gauge in 2017, and a flat or low-slope roof has to shed a storm like that without holding it. Florida's code counts a roof as drained when it clears within 48 hours, and it requires edge metal designed for wind, which matters in a city whose airport logged a 72-knot gust in 2024.

Updated October 2026

A low-slope roof section covered in a granulated cap sheet beside a gray shingle slope, with neighboring rooftops, palms and trees under a pale sky.

Local know-how

Leesburg's rental and commercial roofs under one code

Leesburg counts 14,883 housing units, and renters occupy 37.4 percent of its occupied homes, since owners hold 62.6 percent. Many of the city's roofs therefore belong to people who do not live under them. Inside the city limits, commercial and multifamily roof work is permitted and inspected by the City of Leesburg Building Department under the 2023 Florida Building Code, 8th edition, until applications filed on or after December 31, 2026 move to the 9th edition.

The code names low-slope membranes by their standards: EPDM under ASTM D4637, TPO under D6878, and modified bitumen under its own set of ASTM specifications. New low-slope roofs need a design slope of at least 1/4 inch per foot so water can move to the drains.

Low-slope roofs

Water and wind at the edges of a Leesburg flat roof

Drainage comes first. Positive drainage means the roof clears within 48 hours of rain, the same test NRCA's membrane manual uses for ponding. If a parapet or raised edge would trap water when the main drains back up, the code requires secondary overflow drains or scuppers. Drains themselves are sized on the 100-year hourly rainfall rate, which NOAA Atlas 14 puts at 3.91 inches an hour in Leesburg.

Edges come second. Roof decks and coverings are designed for the wind loads in Chapter 16 of the building code, and metal edge systems on built-up, modified bitumen and single-ply roofs must pass the ANSI/SPRI ES-1 tests or RAS 111. A gutter that also holds down a membrane edge has a test of its own, SPRI GT-1. Those details earn their keep in a city whose airport has recorded gusts of 60 knots in Irma and 72 in Milton.

Questions

Commercial roofing in Leesburg: questions

Can a roof coating solve ponding on a Leesburg flat roof?

Not by itself. The building code holds roof coatings to its fire classification rules and to named ASTM standards, such as D6694 for silicone, and one silicone maker markets its product for areas where ponding may occur. Water that still stands 48 hours after rain, though, is a slope or drain problem first. Florida contractor law also treats any coating sold to stop leaks or extend a roof's life as roofing work. In a summer averaging 19.49 inches of rain at Leesburg's airport station, fix the drainage before picking the coating.

Source: 2023 Florida Building Code, Building, 8th ed., Chapter 15 (UpCodes viewer, unofficial transcription), read Oct 5, 2026

What is TPO, and how does it compare with EPDM on a Leesburg building?

Both are single-ply membranes, and the Florida Building Code names each by its ASTM standard: TPO under D6878, a thermoplastic polyolefin sheet with reinforcing fabric or scrim, and EPDM under D4637. In the 2023 Florida code both sit in section 1507.12, the single-ply section. Whichever one goes on, it must be designed for Chapter 16 wind loads and slope at least 1/4 inch per foot on a new roof. In Leesburg, where Irma's gust at the airport reached 60 knots, wind design is part of the choice from the start.

Source: 2023 Florida Building Code, Building, 8th ed., Chapter 15 (UpCodes viewer, unofficial transcription), read Oct 5, 2026

What rainfall rate are roof drains sized for in Leesburg?

The plumbing code sizes storm drainage on the 100-year hourly rainfall rate from its own map, or on rates from approved local weather data. NOAA Atlas 14 gives 3.91 inches an hour for that storm at Leesburg's 2020 Census point, and 12.8 inches an hour for the same storm's five-minute burst. Roof drains follow the hourly figure, while SMACNA-style gutter tables use the burst, so the two methods size the same rain very differently. New commercial work inside the city goes through plan review at the City of Leesburg Building Department.

Source: 2023 Florida Building Code, Plumbing, 8th ed., Chapter 11 (UpCodes viewer, unofficial transcription), read Oct 5, 2026

Related: Commercial roofing

Nearby

Commercial roofing near Leesburg

Sources for this page(32)
  1. 1.NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Irma (AL112017). Read Oct 5, 2026.
  2. 2.NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Milton (AL142024). Read Oct 5, 2026.
  3. 3.Housing units (ACS 5-year): 14,883. U.S. Census Bureau, American Community Survey 2020-2024 5-year estimates (acs2024_5yr), table B25001 (Housing Units), via Census Reporter API. Read Oct 5, 2026.
  4. 4.Owner-occupied share of occupied homes: 62.6%. U.S. Census Bureau, American Community Survey 2020-2024 5-year estimates (acs2024_5yr), table B25003 (Tenure), via Census Reporter API. Read Oct 5, 2026.
  5. 5.Permit office: City of Leesburg Building Department. City of Leesburg Building Department. Read Oct 5, 2026.
  6. 6.Hurricane Irma (2017). NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Irma (AL112017). Read Oct 5, 2026.
  7. 7.NOAA NCEI U.S. Climate Normals 1991-2020, annual/seasonal (normals-annualseasonal-1991-2020), NCEI Access Data Service. Read Oct 5, 2026.
  8. 8.2023 Florida Building Code, Building, 8th ed., Chapter 15 (UpCodes viewer, unofficial transcription). Read Oct 5, 2026. FBC text read from UpCodes (unofficial transcription): check floridabuilding.org or the ICC viewer before quoting (spec 8.7). Source URL inherited from C-14 (the research cites it "as C-14").
  9. 9.Florida Roofing and Sheet Metal Contractors Association (FRSA). Read Oct 5, 2026.
  10. 10.2023 Florida Building Code, Plumbing, 8th ed., Chapter 11 (UpCodes viewer, unofficial transcription). Read Oct 5, 2026. FBC text read from UpCodes (unofficial transcription): check floridabuilding.org or the ICC viewer before quoting (spec 8.7).
  11. 11.ASTM International. Read Oct 5, 2026.
  12. 12.FBC-B 2023 Ch. 15. Read Oct 5, 2026. FBC text read from UpCodes (unofficial transcription): check floridabuilding.org or the ICC viewer before quoting (spec 8.7). Source URL inherited from C-14 (the research cites it "as C-14").
  13. 13.FRSA, "New 2023 FBC Eighth Edition is Now in Effect", 2024-02-13. Read Oct 5, 2026.
  14. 14.Miami-Dade County RER notice. Read Oct 5, 2026.
  15. 15.apoc.com. Read Oct 5, 2026.
  16. 16.Fla. Stat. 489.105(3)(e). Read Oct 5, 2026.
  17. 17.FBC-B 2023 Ch. 1. Read Oct 5, 2026.
  18. 18.City of Leesburg, Building Department, City of Leesburg. Read Oct 5, 2026.
  19. 19.NOAA Atlas 14 Volume 9 version 2, partial-duration point estimates at the Leesburg 2020 Census internal point (28.7172, -81.9031), NOAA Hydrometeorological Design Studies Center. Read Oct 5, 2026.
  20. 20.Florida Statutes, section 627.7011 (2026), Florida Legislature. Read Oct 4, 2026.
  21. 21.Citizens Property Insurance Corporation, Citizens Property Insurance Corporation. Read Oct 4, 2026.
  22. 22.Florida Building Commission, "Florida Building Code Effective Dates", Florida Building Commission. Read Oct 5, 2026.
  23. 23.FBCR Ch. 9, International Code Council (Florida Building Commission). Read Oct 4, 2026.
  24. 24.Florida Statutes, section 553.844 (2026), International Code Council (Florida Building Commission). Read Oct 5, 2026.
  25. 25.Florida Statutes, section 553.842 (2026), The Florida Senate. Read Oct 5, 2026.
  26. 26.FEMA FL-RA2, FEMA. Read Oct 5, 2026.
  27. 27.eng.ufl.edu, University of Florida / UF/IFAS. Read Oct 5, 2026.
  28. 28.OIR form, Florida Office of Insurance Regulation. Read Oct 4, 2026.
  29. 29.NOAA Atlas 14 (HDSC Precipitation Frequency Data Server), NOAA Hydrometeorological Design Studies Center. Read Oct 5, 2026.
  30. 30.NOAA National Centers for Environmental Information, NOAA National Centers for Environmental Information. Read Oct 5, 2026.
  31. 31.Florida Statutes, section 215.5586 (2026), Florida Legislature. Read Oct 4, 2026.
  32. 32.My Safe Florida Home program, My Safe Florida Home program. Read Oct 5, 2026.

South Fork Roofing

Commercial roofing in Leesburg

Answer a few questions about the job, or call.

CallGet a quote