Gutters · Mangonia Park
Seamless gutter installation, repair and guards in Mangonia Park, FL
A 10-year storm in Mangonia Park drops rain at 11.1 inches an hour for five minutes, and a 100-year burst reaches 16.2. Standard builder-grade gutters are often too small for that. Sizing the gutter and the downspouts to the burst, not the yearly average, decides whether water leaves your roof or spills over it.
Updated November 2026

Our workMangonia Park figures this page uses
- Median year homes were built
- 1981
- Single-family detached share of housing units
- 24.5%
- Housing units (ACS 5-year)
- 943
- Share of homes in buildings with 10+ units
- 14.2%
Rainfall and sizing
How hard the rain falls in your area determines which gutter size you need
Gutters get overwhelmed by the number from the five-minute burst. At this town, a 25-year storm reaches 13.1 inches an hour and a 100-year storm reaches 16.2. Over a full hour, a 10-year storm falls at 3.45 inches, and a 24-hour 10-year storm totals 9.26 inches.
IllustrationIllustration: downpour with gutter
Florida's plumbing code sizes horizontal gutters by the flow off the roof surface. A 5-inch half-round gutter at the code's 1/8 inch per foot slope carries 74 gpm, and a 6-inch carries 110 gpm. By our arithmetic, that makes the 6-inch gutter about 49 percent more capable. On a roof that sheds a lot of water, the larger size is the safer pick.
Downspouts limit the system too. Flow capacity is 92 gpm for a 2 1/2 by 3 inch leader and 192 gpm for a 3 by 4 1/4 inch leader. The code also tells you to add half the area of any wall that drains onto the roof, which matters on two-story sections that dump onto a lower roof.
Code and discharge
Downspout rules for older Mangonia Park homes
With a median build year of 1981, many homes here were built before today's drainage habits. Florida Building Code Residential R318.5 requires gutters with downspouts where eaves project less than 6 inches, except at gable rakes or on a roof above another roof. If your eaves are short, expect the code to ask for them on a re-roof.
At least 1 foot from the sidewall is how far every downspout has to discharge, whether through underground pipe, a tail extension or a splash block. That rule sits in a termite-protection section, so water pooling at the slab is more than a drainage nuisance. Only 24.5 percent of housing units here are single-family detached, so check whether your building shares walls or lot lines before choosing where the water goes.
Gutters on one- and two-family homes must be metal or plastic made for outdoor exposure, with lapped, soldered or caulked joints and corrosion-resistant fasteners. Roof permits are handled by the Town of Mangonia Park Building, Planning & Zoning office. Confirm with them whether gutter work alone needs a permit.
Upkeep
Cleaning schedule for the wet season
At West Palm Beach Intl Airport, 67.3 percent of the 61.75 inches of normal annual rain falls May through October, with August the wettest at 8.68 inches. Clean gutters before May, not after the first storm. The hurricane season runs June 1 to November 30, so a clogged gutter in June meets the heaviest months unprepared.
A Florida insurer recommends cleaning at least twice a year, spring and fall, and more often under overhanging trees. September through November is when pine needles drop most heavily. A worn shingle roof can also be the reason granules build up in your gutters.
Thunder means stay off the ladder. NWS Miami tells people not to work on roof tops or other high places when thunder can be heard.
Rain on your roof
Preset: 9.26 inches, the 10-year 24-hour rain (NOAA Atlas 14 at Mangonia Park).
11,538 gallons run off that roof, all of it toward the gutters and downspouts.
Math: square feet × inches × 0.623 gallons.
Repair and guards
Gutter repair and guards in Mangonia Park
Mangonia Park downpours can overwhelm an undersized run in minutes, so a gutter may overflow without a single leaking joint. South Fork Roofing repairs a run when its channel and supporting board are sound, replaces it when damaged or too small, and adds fine-mesh guards wherever branches overhang the gutters.
Questions
Gutters in Mangonia Park: questions
What size gutters do I need in Mangonia Park?
Size them to the burst rate, which is 11.1 inches an hour for five minutes in a 10-year storm here. Code capacities run from 74 gpm for a 5-inch half-round to 110 gpm for a 6-inch at 1/8 inch per foot slope. A larger roof area, or walls draining onto it, pushes you toward the 6-inch size. Have the installer show you the roof area and the flow rate they used.
Source: NOAA Atlas 14 Volume 9 version 2, partial-duration intensity estimates at the Mangonia Park 2020 Census internal point (26.7586, -80.0761), read Oct 5, 2026
How far from my house must a downspout drain?
At least 1 foot from the sidewall. Under Florida Building Code Residential R318.5, you may use underground piping, tail extensions or splash blocks. With a median build year of 1981 in Mangonia Park, check older downspouts that dump right at the foundation, because that discharge point can fail the rule.
Source: U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25035, via Census Reporter API, read Oct 5, 2026
When should I clean my gutters in Palm Beach County?
Clean before May and again after the autumn leaf and needle fall. At West Palm Beach Intl Airport, 41.56 of 61.75 inches of normal annual rain falls May through October. Pine needle fall peaks September through November. Clean more often under heavy trees, and never climb a ladder when thunder can be heard.
Source: NOAA NCEI U.S. Climate Normals 1991-2020 (access data service), read Oct 5, 2026
Does my roof need gutters at all?
Not always. The code requires gutters with downspouts where eaves project less than 6 inches, with exceptions for gable end rakes and roofs above other roofs. If your eaves project 6 inches or more, the rule may not apply. Homes in Mangonia Park were built around a median year of 1981, so many roofs there have older eave details that are worth measuring before you assume anything. Ask Mangonia Park Building, Planning & Zoning how it reads your roof.
Source: Town of Mangonia Park - Building, Planning & Zoning, read Oct 5, 2026
Sources for this page(37)
- 1.Median year homes were built: 1981. U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25035, via Census Reporter API. Read Oct 5, 2026.
- 2.U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25035, via Census Reporter API. Read Oct 5, 2026.
- 3.Single-family detached share of housing units: 24.5%. U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25024, via Census Reporter API. Read Oct 5, 2026.
- 4.Permit office: Town of Mangonia Park - Building, Planning & Zoning. Town of Mangonia Park - Building, Planning & Zoning. Read Oct 10, 2026.
- 5.NOAA NCEI U.S. Climate Normals 1991-2020 (access data service). Read Oct 5, 2026.
- 6.NOAA NCEI U.S. Climate Normals 1991-2020 (access data service). Read Oct 5, 2026.
- 7.NOAA National Hurricane Center, Tropical Cyclone Climatology. Read Oct 5, 2026.
- 8.NWS Miami, Weather Safety - Lightning. Read Oct 5, 2026.
- 9.U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25003, via Census Reporter API. Read Oct 5, 2026.
- 10.Hurricane Matthew (2016). NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Matthew (AL142016). Read Oct 5, 2026.
- 11.Housing units (ACS 5-year): 943. U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25001, via Census Reporter API. Read Oct 5, 2026.
- 12.Share of homes in buildings with 10+ units: 14.2%. U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25024, via Census Reporter API. Read Oct 5, 2026.
- 13.Mobile homes, share of housing units: 0.4%. U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25024, via Census Reporter API. Read Oct 5, 2026.
- 14.2023 Florida Building Code, Plumbing, 8th ed., Chapter 11 (UpCodes viewer, unofficial transcription). Read Oct 5, 2026.
- 15.2023 Florida Building Code, Residential, 8th ed., R318.5 (UpCodes viewer, unofficial transcription); FBC-Building 1503.7. Read Oct 5, 2026.
- 16.2023 Florida Building Code, Residential, 8th ed., Chapter 8 (UpCodes viewer, unofficial transcription). Read Oct 5, 2026.
- 17.2023 Florida Building Code, Residential, 8th ed., Chapter 9 (UpCodes viewer, unofficial transcription). Read Oct 5, 2026.
- 18.thig.com. Read Oct 5, 2026.
- 19.ufdcimages.uflib.ufl.edu. Read Oct 5, 2026.
- 20.Owens Corning, "3 Signs That It's Time to Replace Your Roof". Read Oct 5, 2026.
- 21.consumerreports.org. Read Oct 5, 2026.
- 22.NOAA Atlas 14 Volume 9 version 2, partial-duration intensity estimates at the Mangonia Park 2020 Census internal point (26.7586, -80.0761), NOAA Hydrometeorological Design Studies Center. Read Oct 5, 2026.
- 23.NOAA Atlas 14 Volume 9 version 2, partial-duration 24-hour depth estimates at the Mangonia Park 2020 Census internal point (26.7586, -80.0761), NOAA Hydrometeorological Design Studies Center. Read Oct 5, 2026.
- 24.Town of Mangonia Park - Building, Planning & Zoning, tompfl.com. Read Oct 5, 2026.
- 25.NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Matthew (AL142016), NOAA National Hurricane Center. Read Oct 5, 2026.
- 26.NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Dorian (AL052019), NOAA National Hurricane Center. Read Oct 5, 2026.
- 27.Florida Building Commission, 'Setting New Standards for Safety: The Florida Building Code' (2004 publication; wind-speed figures in it are outdated and not used), Florida Building Commission. Read Oct 5, 2026.
- 28.U.S. Census Bureau, American Community Survey 2024 5-year estimates (2020-2024), table B25035, B25034, B25024, via Census Reporter API, U.S. Census Bureau (via Census Reporter). Read Oct 5, 2026.
- 29.Florida Statutes, section 627.7011 (2026), Florida Legislature. Read Oct 4, 2026.
- 30.2023 Florida Building Code, Building, 8th ed., Chapter 15 (UpCodes viewer, unofficial transcription), UpCodes (Florida Building Code transcription). Read Oct 5, 2026.
- 31.Miami-Dade County RER notice, Miami. Read Oct 5, 2026.
- 32.Florida Statutes, section 553.842 (2026), Florida Legislature. Read Oct 5, 2026.
- 33.NOAA National Hurricane Center, Tropical Cyclone Report: Hurricane Irma (AL112017), NOAA National Hurricane Center. Read Oct 5, 2026.
- 34.Wikipedia, 'Mangonia Park, Florida' (revision 1378541505), Wikipedia. Read Oct 5, 2026.
- 35.Wikipedia, 'List of municipalities in Florida', Wikipedia. Read Oct 5, 2026.
- 36.2023 Florida Building Code, Building, 8th ed., Chapter 1 (UpCodes viewer, unofficial transcription), UpCodes (Florida Building Code transcription). Read Oct 5, 2026.
- 37.NOAA Atlas 14 at Mangonia Park: 11.1 in/hr (5-minute, 10-year). NOAA Atlas 14 Precipitation Frequency Data Server. Read Oct 5, 2026.